As a professional high quality RS485 3 Phase Din Rail Digital Meter manufacturer, you can rest assured to buy RS485 3 Phase Din Rail Digital Meter from our factory. And we will offer you the best after-sale service and timely delivery.RS485 3 Phase DIN Rail Digital Meter is designed to measure three phase four wire AC active energy like residential , utility and industrial application. It is a long life meter with the advantage of high stability , high over load capability , low power loss and small volume .
Wenzhou Changjiu Technology Co., Ltd. is a professional China RS485 3 Phase Din Rail Digital Meter manufacturer and supplier, known for its quality service. Adhering to the pursuit of perfect quality of products, so that our RS485 3 Phase Din Rail Digital Meter have been satisfied by many customers. In order to ensure the quality and customer needs, we have cooperated with domestic power groups with strong production strength. We will strictly screen each supplier and send videos to customers to watch.
1) Maximum current 100A direct access
2) DIN Rail mounting, standard 4 modulus width.
3) Touch button design improves button operability and reduces button failure rate
4) Multi-function parameter measurement, providing voltage, current, active power, reactive power, apparent power, power factor, phase Angle, etc.
5) To provide the analytical data of the total harmonic contents of voltages and currents. Provide a variety of statistical data and local storage functions, such as two-way power, demand and other statistical data.
6) Provide monthly electricity consumption statistics for the last 12 months and daily electricity consumption statistics for the last 31 days
7) supports the dual-timing function of the meter startup running time and load running time.
8) supports the access of a 2-tariff switching signal for metering at 2-tariff energy.
9) Support RS485 communication function, baud rate up to 38400bps, support Modbus RTU, Mbus(Option) protocol.
10) Supports one optocoupler pulse output interface, and output parameters can be set.
11) LCD refresh time is 1 second, support manual or automatic scroll display (configurable)
Model |
DAC4300/DAC4301/DAC4302/DAC4300CT/DAC4301CT/DAC4302CT |
|
Electrical Characteristics |
Rate voltage (Un) |
3*110/190V or 230/400V AC |
Operational voltage |
L-N: 85 to 275V AC; L-L: 85 to 480V AC |
|
Overload capacity of voltage |
2*Un for 1 second |
|
Rate current(Ib) |
5A |
|
Maximum current(Imax) |
100A |
|
Operational current |
0.1%Ib to Imax |
|
Overload capacity of current |
30*Imax for 0.01 second |
|
Operational frequency range |
45 - 65Hz |
|
Power consumption |
<2W/10VA |
|
Pulse constant |
400 imp/kWh |
|
Display |
LCD with backlight |
|
Maximum reading of energy |
9999999.9 kWh/kVarh |
|
Measure type |
Three phase four wire, Three phase three wire,Single phsae two wire |
|
Measurement accuracy |
Voltage, Current |
±0.5% |
Active power |
±1.0% or 0.5% |
|
Reactive power |
±2.0% |
|
Apparent power |
±1.0% |
|
Active energy |
±1.0% or 0.5% |
|
Reactive energy |
±2.0% |
|
Power factor |
±1.0% |
|
Frequency |
±0.2% |
|
Environmental Characteristics |
Operating Temperature |
-25 to +55ºC |
Storage Temperature |
-40 to +80ºC |
|
Humidity |
< 90%, non-condensing |
|
Pollution Degree |
2 |
|
Altitude |
Up to 2000m |
|
Vibration |
10 Hz to 150Hz, IEC 60068-2-6 |
|
IP Degree of Protection |
Designed to IP51 front display, IP30 meter body |
|
Electromagnetic Characteristics |
Electrostatic Discharge |
±8kV(contact discharge),±15kV(air discharge); Level 4, according IEC 61000-4-2 |
Immunity to Radiated Fields |
10V/m,80 - 2000MHz; Level 3, according IEC 61000-4-3 |
|
Immunity to Electrical Fast Transients |
±4kV; Level 4, according IEC 61000-4-4 |
|
Immunity to Surges |
±4kV; Level 4, according IEC 61000-4-5 |
|
Immunity to Conducted Disturbances |
10V,0.15 - 80MHz; Level 3, according IEC 61000-4-6 |
|
Immunity to Magnetic Fields |
IEC 61000-4-8 |
|
Immunity to Voltage Dips |
IEC 61000-4-11 |
|
Radiated Emissions |
Class B, according EN55011 |
|
Conducted Emissions |
Class B, according EN55011 |
|
Harmonics Emissions |
IEC 61000-3-2 |
|
Safety |
Overvoltage Category |
CAT III, according IEC 61010-1 |
Measurement Category |
CAT III, according IEC 61010-1 |
|
Insulation |
AC Voltage Test: 4kV for 1 minute |
|
Impulse Voltage Test: 6kV - 1.2/50µS waveform |
||
Protective Class |
II, according IEC61010-1 |
|
Communications |
Interfaces standard and protocols |
2-wire RS485, Modbus RTU |
Buad rate |
1200 to 38400 bps, default is 9600 bps |
|
Parity bit |
None, Even, Odd, default is None |
|
Stop bit |
1 or 2, default is 1 |
|
Response time |
<100ms |
|
Transmission mode |
half-duplex |
|
Transmission distance |
Up to 1000m |
|
Max. Bus loading |
64 pcs |
|
Pulse output |
Interface type |
Open collector optocoupler |
Pulse constant |
Per pulse equal 0.001/0.01/0.1/1 kWh/kvarh (Configurable) |
|
Pulse width |
60/100/200 milliseconds (Configurable), default is 100milliseconds |
|
Pulse output type |
Import/export/total active energy, Import/export/total reactive energy (Configurable) |
|
Class |
Class A, according IEC 62053-31 |
|
Input voltage |
5 to 27 VDC |